Download KSC Driver

Posted on
TS-990S, TS-890S, TS-590SG, TS-590S, TH-D72A/E
KPG-22U, KPG-46U, KPG-186U
Virtual COM Port Driver
Last updated : August 21, 2019
Introduction
Thank you for choosing the KENWOOD transceivers. You can connect your TS-990S, TS-890S, TS-590SG, TS-590S, or TH-D72A/E to a PC via a USB cable, or you can connect your TH-K20A/E, TH-K40A/E, TM-281A/E, TM-481A, or other transceivers to a PC via the KPG-22U/46U/186U programming cables by installing the virtual COM port driver in the PC, and then utilize the Radio Control Program, Memory Control Program, or other software we have provided.
This virtual COM port driver installation program is provided by Silicon Laboratories Inc.
After reading through the following explanations, feel free to download and install the software.
Operating Environment
1.Operating System (OS)
Windows® 7 (32-bit or 64-bit)
Windows® 8.1 (32-bit or 64-bit)
Windows® 10 (32-bit or 64-bit)
2.Peripheral Devices
USB 2.0 interface.
Installing the virtual COM port driver
ATTENTION: Do not connect the device to a PC before installing the virtual COM port driver.
Extract the downloaded file ('CP210x_Windows_Drivers.zip' for Windows® 7/8.1, or 'CP210x_Universal_Windows_Driver.zip' for Windows® 10) into a designated folder.In the designated folder, a folder labeled 'CP210x_Windows_Drivers' or 'CP210x_Universal_Windows_Driver' will be created.
In the created folder, double click the 'Cp210xVCPInstaller_x86.exe' with 32-bit OS, or the 'Cp210xVCPInstaller_x64.exe' with 64-bit OS, and follow the instructions that appear on the display to install the virtual COM port driver.
Connecting the device to a PC
Turn the transceiver power ON, then connect it to a PC via a connection cable for the transceiver. The PC will detect new hardware.
The installation of the device driver software will start automatically.
If a reboot request appears, please reboot the PC.
Confirming the COM port number
Open the 'Device Manager' to confirm which COM port number is assigned for connection with the device.
(Confirm the COM port number after turning on the transceiver and connecting the transceiver to the PC using a USB cable, or after connecting the KPG-22U/46U/186U to the PC.)
For Windows® 7
1. Click the Windows® [Start] button.
2. Right-click [Computer], then click [Properties].
3. Click [Device Manager] in the displayed window.
4. [Device Manager] window will appear.
For Windows® 8.1 and Windows® 10
1. Right-click the Windows® [Start] button.
2. Click [Device Manager] in the displayed window.
3. [Device Manager] window will appear.
Click “Ports (COM & LPT)” to extend it, then you can find “Silicon Labs CP210x USB to UART Bridge (COMxx)”.The “COMxx” number is different depending on your PC.
In the above example, “Silicon Labs CP210x USB to UART Bridge (COM3)” is listed. This means that COM3 is assigned for the connection with the transceiver.
Select this port number in the configurations for communication in the software you are using.
Note:
When connecting a TS-890S transceiver to the PC, 2 virtual COM ports are assigned as follows.
In the TS-890S Menu settings, these 2 virtual COM ports are defined as [Virtual 'Standard' COM Port] and [Virtual 'Enhanced' COM Port].
These 'Standard' and 'Enhanced' virtual COM ports are distinguished as follows.
•Double-click on these in the Device Manager to display the respective Properties windows.
•Select the 'Details' tab and then select 'Location Paths' (or 'Rutas de acceso de ubicación':Español, 'Chemins d'accès des emplacements':Français, 'Speicherortpfade':Deutsch, 'Percorsi':Italiano, 'Locatiepaden':Nederlands) from the Property drop-down menu.
•Move the mouse cursor to the line displayed in the 'Value' column (the top line if multiple lines are displayed) and check the number in the parenthesis on the right end of the character string.
The port displayed with the number (1) is the virtual COM (Standard) port of the transceiver.
In the display example above, the virtual 'Standard' COM port is assigned to COM3.
The port displayed with the number (2) is the virtual COM (Enhanced) port of the transceiver.
In the display example above, the virtual 'Enhanced' COM port is assigned to COM4.
Please also refer to the TS-890S Instruction manual for details.
If you agree with the details listed above, click one of the following links corresponding to each OS to download the virtual COM port driver installation program.
For Windows® 7/8.1:
'CP210x_Windows_Drivers.zip'(v6.7.6) 6.83MB download
For Windows® 10:
'CP210x_Universal_Windows_Driver.zip'(v10.1.8) 878KB download
You can also download the latest and earlier versions virtual COM port driver installation program from the Silicon Laboratories website. (The URL link is subject to change.).
Microsoft®, Windows®, and Windows logo are registered trademarks of Microsoft Corporation in the United States and/or other countries.
  1. Download Ksc Drivers
  2. Download Dsc Drivers For Windows 10
  3. Emudhra Dsc Driver Download

Download Ksc Drivers

This information is primarily designed to help software developers integrate M-S Cash Drawer with their software.

Once integration is complete, this information can also be used by software developers, resellers, and end users for post-sales support.
All our electronic cash drawer models use the same modules/electronics/drivers.

Once you have integrated our Bluetooth, USB, serial, parallel cash drawers, you do not need to make programming changes per cash drawer model.

Our true HID USB cash drawer interface is port driven and does not require a power supply. In some cases our serial, KSC, cash drawers also do not require a power supply.

USB Driver Download for KSC-Y32 The latest KSC-Y32 driver for Windows ® 7(32/64-bit)/Windows ® 8.1(32/64-bit)/Windows ® 10(32/64-bit) can be downloaded to your PC. Read the following Software License Agreement carefully before you start downloading the driver. DriverPack is a comprehensive application designed to simplify the driver installation and updating process to a couple of clicks. All the drivers your system needs in order to work properly are detected automatically and deployed faster than a manual operation.

Our Bluetooth cash drawer interface is USB port driven and does not require a separate power adapter. In the absence of a USB port, you can use a wall adapter that supports a USB A connection.

Bluetooth cash drawer SDK & integration: COMING SOON

Coming soon …

USB & OPOS Cash drawer support

Download Dsc Drivers For Windows 10

Please download USB dll files/drivers, and review programming instructions /examples listed below based on the operating system your software uses.

Please have your team connect with our tech support at 800-544-1749 ext 7230 or [email protected] Alternatively, please advise us who we can speak with to ensure the dll files have been downloaded on the computer and there are no compatibility issues with the software.

Emudhra Dsc Driver Download

Once we are able to confirm that there aren’t any known incompatibility issues or conflicts, we can arrange a demo USB cash drawer for your evaluating/ testing.

USB & OPOS for Windows

  • USB Programming Example
  • Downloads for USB HID Interface for Windows XP, Vista, 7, 8 and 10 (32 bit & 64 bit)
  • Downloads for USB HID OPOS
  • Downloads for USB HID OPOS for Windows 7, 8 and 10 (32 bit & 64 bit)
  • Downloads for legacy USB Interface
  • Downloads for Serial Interface (KSC/KSI) OPOS

Serial & parallel interface cash drawer support

KSC is also referred to as dedicated serial interface. In some cases, it does not require a power supply/adapter.
KSI is also referred to as intelligent interface. It requires a power supply/adapter.
KPC is also referred to as parallel interface. It requires a power supply/adapter.
A splitter, Y cable, is available when it needs port sharing.

Serial Interface

  • KSI Instructions

Parallel Interface

  • KPC Instructions
KSCDownload KSC Driver

Universal Intelligent Interface (KLIC)

  • KLIC Instructions

Cash drawer test utilities

Windows based test Utility:

Instructions:

KSC

This utility will only work on systems using Windows operating systems. Click on the Download link and save the file on the desktop. Go to the desktop (windows key + d) and double click on the file to start**.

In order to use the test utility you must identify the type of cash drawer
you are using:

  • Parallel interfaced (KPC)
  • Serial interfaced

– KC (single serial cable exiting the back of drawer, plug to connect power supply)

– KSC (female plug for 9 pin serial cable, plug to connect power supply, set of 4 dipswitches)

– KSI (female plug for 9 pin serial cable, plug to connect power supply, set of 10 dipswitches)

  • Be sure to reset the dipswitches as shown in the utility, remember to disconnect the power supply from the drawer and reconnect the power supply after every change of the dipswitches.
  • Printer-interfaced (Connecting through a receipt printer) either STAR, Ithaca, Epson or Citizen.

If the test utility opens the cash drawer then you may have a configuration problem with your point-of-sale software, and you would need to contact your software vendor.

**Some windows installations might also need Visual Basic runtime files. These files are also available for download.

Download Test Utility Download Visual Basic Runtime

MS DOS based test utility:

Download Test Utility